First, the maintenance sequence of the dehumidifier without dehumidification failure:
1. Ventilation system failure:
1 inlet grille and outlet grille: A. Man-made damage or aging cracks; B. Ingress or out of the wind is severely blocked;
2 air filter: blocked or damaged by dust;
3 evaporator: A. Evaporator condenser fins dust; B. The surface of the evaporator freezes;
4 fan motor: A. Capacitor damage; B. Fan motor holding shaft; C. Rotor and shaft loose; D. Axis bending deformation; E. Bearing damage; F. Winding burned;
5 wind blade: A. Loose screws; B. Fan blade deformation or damage; C. The dust of the wind blade is serious, which seriously affects the air volume; D. The small dehumidifier blades also have a phenomenon of seizing the blades due to serious dust accumulation.
2. Electrical system failure:
1 compressor and fan are not turned: A. The power is cut off; B. The switch is not closed; C. Socket disconnection; D. The voltage is too low; E. The circuit breaker is disconnected; F. The fuse is blown.
2The compressor does not turn, the fan turns: A. Starter failure; B. Capacitor failure; C. Overload protection.
3 compressor and fan are running: the refrigeration system is faulty.
3. Refrigeration system failure:
1 refrigerant leakage;
2 refrigeration system blockage: A. Dirty blockage; B. Oil plug; C. Welding plug
3 excess refrigerant;
4 The compressor has no displacement (fault).
4. Compressor failure:
1 poor compression, high and low pressure chamber helium;
2 The running parts are damaged and the compressor holds the shaft.
Second, the maintenance sequence of the dehumidifier noise increase fault:
1. The ground is not flat and the dehumidifier is not placed smoothly;
2. Loose parts on the dehumidifier;
3. There is a foreign object in the dehumidifier;
4. Damage or deformation of the fan blade causes the dynamic balance to be destroyed;
5. Starter failure;
6. There is a collision between the pipelines;
7. The fan is short of oil;
8. Fan bearing failure;
9. The compressor is too noisy;
10. Filling with too much refrigerant or lubricating oil will cause liquid shock.
Third, the maintenance sequence of the dehumidifier running water to the ground:
1. The dehumidifier is placed unbalanced, and the water tank is excessively tilted, causing water to overflow;
2. The drain hole or drain pipe of the sink is blocked;
3. The water tank is damaged and leaks;
4. Leakage at the outlet of the outlet pipe or aging of the outlet pipe.
4. The troubleshooting sequence of normal operation but dehumidification effect is worse:
1. The air filter has serious dust accumulation and the airflow is blocked;
2. The air outlet attracts obstacles and the airflow is blocked;
3. The fan speed is slower;
4. The room is poorly sealed, and a large amount of outdoor humid air infiltrates;
5. The room size is too large;
6. Excessive moisture in the room;
7. More dust accumulates on the fins of the evaporator, which reduces the effect of freezing and dehumidifying;
8. Frost on the surface of the evaporator;
9. There is more oil in the evaporator, and the cooling and dehumidification effect is reduced;
10. Insufficient refrigerant charge;
11. Refrigerant leakage;
12. The capillary specifications are incorrect, the diameter of the tube is large, and the throttling is insufficient.
13. Ice blockage occurs in the refrigeration system;
14. The refrigeration system is partially blocked;
15. There is air in the refrigeration system;
16. The compressor is poorly compressed and the displacement is reduced.
5. The troubleshooting sequence of the compressor can not be started:
1. Power failure, voltage is too low;
2. The circuit fuse is blown or the switch is damaged;
3. The starting capacitor is damaged;
4. Overheat protection is not reset or faulty;
5. Various relays have not been reset or malfunctioned;
6. Motor winding is broken or burned
LCZ696 Intermediates
LCZ696 (Valsartan/sacubitril) is a combination drug for use in heart failure developed by Novartis. It consists of the angiotensin receptor blocker valsartan and the neprilysin inhibitor sacubitril, in a 1:1 mixture by molecule count. It may be used instead of an ACE inhibitor or an angiotensin receptor blocker in people with heart failure with reduced ejection fraction. The combination is sometimes described as an "angiotensin receptor-neprilysin inhibitor" (ARNi).
It was approved under the FDA's priority review process on July 7, 2015. It is also approved in Europe.
We produce a series of complete intermediates for LCZ696, intermediate I (CAS No. 1426129-50-1) and intermediate II (CAS No. 1012341-50-2) etc.
All of our products are with stable production and strict quality control, making sure your experience with Sunshine Biotech is always enriching, satisfying and fulfilling.
Lcz696 Intermediates,Cas 1426129-50-1,Cas 1012341-50-2,High Purity Lcz696 Intermediate
Nanjing Sunshine Biotech Co., Ltd , https://www.sunshine-bio.com